Use a non-combustible floor protector under the unit, extending 6” (150mm) past the side of unit (or less if installed
at closer clearances) and 6” (150mm) in front of UBB door.
Alcove Dimensions (Rear Vent Only):
• Minimum Height - 62” (1575mm),
• Minimum Width - 35.5” (902mm),
• Maximum Depth - 24” (610mm)
B
A
B
C
D
D
Freestanding and Alcove (rear only) Installation Clearances:
A 10.5” (267mm) D 6” (150mm)
B 2” (50mm) E 3” (75mm)
C 22” (560mm)
NOTE: Minimum clearances are for temperature concerns and do not allow for enough room for maintenance.
Please allow enough room on the sides for routine maintenance, 6” - 12” (150mm - 305mm) of clearance to non-
movable objects (i.e. walls) is recommended. Also, clearance to the back of the UBB is needed for replacement of
the filter.