19

8. Place the Vertical Support Clamp (5000576), around the top of the
hole in the bottom of the Support Box. See Figure 21.
9. Connect the necessary amount of pipe sections to reach the UBB at a
point where the Vent Cap will extend a minimum of 24 inch (61 cm)
above the roof. See Figure 22.
10. Run the assembled pieces of vent pipe down through the Clamp of
the Support Box and connect to the appliance with an Elbow and
Starter Collar. See General Vent Installation Instructions for details on
connecting the pipe together.
11. Using a level, make slight adjustments in the position of the appliance
until the pipe is truly vertical. Tighten the bolts in the Clamp.
12. Slip the Flashing over the pipe section(s) protruding through the roof.
Secure the base to the roof with roofing nails. Insure that the roofing
material overlaps the top edge of the Flashing. See Figure 22.
13. Seal all nail heads with high-temperature waterproof sealant. To
finish, apply high-temperature waterproof sealant where the Storm
Collar will meet the Vent and Flashing; slide Storm Collar down until it
sets on the Flashing, put the Vent Cap on and push to lock. See Figure
14 (page 16).


Clamp
Vent Cap
Storm
Collar
Roof Flashing
Cathedral Ceiling
Support Box
Vent Pipe
24 in
(610mm)

Due to cleaning, inspection, and condensation issues, Bixby Energy no longer recommends connecting the UBB to an existing Class
A chimney.

Due to cleaning, inspection and condensation issues, Bixby Energy no longer recommends connecting the UBB to an existing masonry
chimney. The venting may pass though the chimney to the outside; see previous pages for horizontal venting information.